無菌室的要求
Asepsis room requirements
1.工作室應矮小、平整,面積只需4米2左右,高2.2—2.3米,內部裝修應平整、光滑,無凹凸不平或棱角等,四壁及屋頂應用不透水之材質,便于擦洗及殺菌
The 1. studio should be short, flat area, only 4 meters high around 2, 2.2 - 2.3 meters, interior decoration should be flat and smooth, no edges or uneven walls, roof and application of impervious material, easy scrubbing and sterilizing
2.室內采光面積大,從室外應能看到室內情況。無菌室裝修公司
2., indoor lighting area is large, from the outside should be able to see the indoor situation.
3.為保證無菌室的潔凈,無菌室周圍需設緩沖走廊,走廊旁再設緩沖間,其面積可小于無菌室。
3.,in order to ensure the asepsis room clean, asepsis room around need to set up buffer corridor, corridor next to buffer room, its area is smaller than the asepsis room.
4.無菌室、緩沖走廊及緩沖間均設有日光燈及供消毒空氣用紫外燈,殺菌紫外燈離工作臺以1米為宜 ,其電源開關均應設在室外。
4. asepsis room, buffer corridors and buffer rooms are equipped with fluorescent lamps and ultraviolet light for disinfection of air, bactericidal UV lamp 1 meters away from the work table is appropriate, and its power switch should be located outdoors.
5.無菌室與緩沖間進出口應設拉門,門與窗平齊,門縫要封緊,兩門應錯開,以免空氣對流造成污染。
5. asepsis room and buffer room should be located between doors and windows, doors and windows flush, the door should be sealed tight, two doors should be staggered so as not to air convection pollution.
6.無菌室的使用與管理
6. asepsis room use and management
無菌室應保持清潔整齊,室內僅存放必須的檢驗用具如酒精燈、酒精棉、火柴、鑷子、接種針、接種環(huán)、玻璃鉛筆等。不要放與檢測無關的物品,室內檢驗用具及凳桌等保持固定位置,不隨便移動。每2—3周用2%石炭酸水溶液擦拭工作臺、門、窗、桌、椅及地面,然后用3%石炭酸水溶液噴霧消毒空氣,然后紫外燈殺菌半小時,定期檢查室內空氣無菌狀況,細菌數應控制在10個以下,發(fā)現不符合要求時,應立即徹底消毒滅菌。
Asepsis room should be kept clean and tidy, and only necessary inspection tools such as alcohol lamp, alcohol cotton, matches, tweezers, inoculation needle, inoculation ring and glass pencil will be kept in the room. Do not place items such as inspection equipment, stools, tables and so on, and do not move freely. Every 2 - 3 weeks with 2% phenol aqueous solution wipe the table, door, window, desk, chair and the ground, and then 3% phenol aqueous solution spray disinfection of air, the ultraviolet lamp sterilization for half an hour, the indoor air condition of sterile regular inspection, bacteria should be controlled in the following 10 months, that does not meet the requirements immediately, complete sterilization.
我們的熱忱,一如既往!我們的追求,永無止境!我們的服務,精益求精!歡迎來電咨詢!
Our enthusiasm, as always! Our pursuit is endless! Our service, excellence! Welcome to inquire!